Welltech SPCI2S Intel NetStructure SS7 Boards Manuel d'utilisateur Page 104

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 107
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 103
SS7 Programmers Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 104
A3 ISUP Parameters
A3.1 Global ISUP Configuration
Syntax: ISUP_CONFIG <res1> <res2> <user_id> <options>
<num_grps> <num_ccts> [<partner_id>]
Example: ISUP_CONFIG 0 0 0x2d 0x0435 4 128
The global configuration parameters for the ISUP module.
<res1>, <res2>
Reserved for backwards compatibility. These fields should be set to zero.
<user_id>
The module_id of the application running on the host that will use the ISUP module.
<options>
A 16 bit value containing global run-time options for the operation of the ISUP module. The meaning
of each bit is as defined for the ’options’ parameter in the ISUP Configure Request message as
detailed in the
ISUP Programmer’s Manual
<num_grps>
The maximum number of ISUP circuit groups that the user intends to use. This must not exceed the
maximum number of circuit groups supported otherwise module configuration will fail. Typically
<num_grps> should be set to the maximum number of circuit groups supported.
<num_ccts>
The maximum number of ISUP circuits that the user intends to use. This must not exceed the
maximum number of circuits supported otherwise module configuration will fail. Typically <num_ccts>
is set to 32 times the number of groups for E1 operation and 24 times the number of circuit groups
for T1 operation.
NOTE: The valid range for the circuit identifier (cid) is from zero up to one less than the maximum
number of circuits (num_ccts).
<partner_id>
Optional parameter for use when operating in dual resilient configuration. This parameter is the
module_id of the ‘partner’ ISUP module (equivalent to the ‘module_id field in the ISUP Configure
Request message as documented in the
ISUP Programmer’s Manual
).
A3.2 ISUP Circuit Group Configuration
Syntax: ISUP_CFG_CCTGRP <gid> <dpc> <base_cic> <base_cid> <cic_mask> <options>
<user_inst> <user_id> <opc> <ssf> <variant> <options2>
Example: ISUP_CFG_CCTGRP 0 3 1 1 0x7fff7fff 0x00000003 0 0x2d 2 0x8 4 0x00000000
The configuration parameters for a group of ISUP circuits. Usually a group is all the circuits on a
single E1 or T1 interface.
Vue de la page 103
1 2 ... 99 100 101 102 103 104 105 106 107

Commentaires sur ces manuels

Pas de commentaire

Bowers & Wilkins Subwoofer Benutzerhandbücher

Beginnend mit A

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
ASW 12CM
Bedienungsanleitung      Bowers & Wilkins ASW 12CM User's Manual, 104 Seiten
ASW 2500
Bedienungsanleitung        Bowers & Wilkins ASW 2500 User's Manual, 38 Seiten
ASW1000
Bedienungsanleitung   Bowers & Wilkins ASW1000 User's Manual, 1 Seiten
ASW2000
Bedienungsanleitung         Bowers & Wilkins ASW2000 User's Manual, 45 Seiten
ASW608
Bedienungshandbuch      Bowers & Wilkins ASW608, 104 Seiten